Rigel 288

Hand-held Electrical Safety Analyzer

  • IEC / EN 60601-1 / 62353 / NFPA-99
  • On-board memory and keyboard
  • Automatic and manual test sequences
Rigel 288 Biomedical Electrical Safety Analyzer

Rigel 288 Biomedical Electrical Safety Analyzer

Click
to Request a Quote

The Rigel 288 biomedical electrical safety analyzer has become the most recognized electrical safety analyzer on the market today. Its unique design, patented earthbond technology and use of internal memory make the Rigel 288 biomedical electrical safety analyzer a truly valuable tool for every biomedical test professional.

Combining automatic and manual test sequences, data logging and direct printing facilities, the Rigel 288 biomedical electrical safety analyzer is the most compact electrical safety analyzer of its kind.

Versatility comes for conformance with several international standards such as: IEC / 62353, 60601-1, NFPA-99 and many local variants.

Bluetooth connectivity to a range of accessories and Med-eBase, comprehensive database software, ensures fast and easy download of test results, managing your asset database, creation of test sequences and producing test certificates.

Rigel 288 Biomedical Electrical Safety Analyzer

Click
to Request a Quote

Technical Specification:

Earth Continuity
Method 2 wire technique, using 'zero' lead function.
Test Current >+200mA, -200mA DC into 2 ohms
Max Test Voltage 4-24V rms o/c (6V for IEC 60601 tests)
Measuring Range
(low range)
0.001 – 0.999 ohms @ 0.001 ohms resolution
Measuring Range
(mid range)
1.00 – 9.99 ohms /@ 0.01 ohms resolution
Measuring Range
(high range)
10.0 – 19.9 ohms @ 0.1 ohms resolution
Accuracy ± 3% of reading + 10 m ohms
Insulation Resistance
Measurement EUT to Earth / Ground, EUT to AP, AP to Ground
Voltage 250V DC, 500 V DC @1mA
Range (low range) 0.01Mohms - 20 Mohms
Accuracy (low range) ± 5% of reading +2 counts
Range (high range) 20Mohms – 100Mohms
Accuracy (high range) ±10% +2 counts
Resolution 0.01Mohms
Direct Leakage Measurement
Measuring Range 4μA to 9999μA
Accuracy ± 5% or reading +2 counts
Mains on A.P. voltage F-type only @ 110% of mains
Measuring Device As per IEC 60601-1 requirements
Measurement Type Separate AC & DC for Patient (-Auxiliary)
True RMS for all remaining Leakage tests
Leakage to IEC 60601
Differential Leakage Measurement
Measuring Range 75μA to 9999μA
Accuracy ±5% of reading + 5 counts
Measurement / display resolution 1μA
Measurement Type True RMS
Measuring Device Similar frequency response characteristics to IEC 60601-1
Alternative Leakage Measurements
Test Voltage 250V at mains frequency
Test Current 3.5 mA current limited
Measurement Range 4μA to 9999μA
Measurement Resolution 1μA
Measurement Accuracy ±5% of reading + 2 counts
Measurement Type True RMS
Measuring Device As per IEC 60601-1
Power Measurement
Method VA rating
Range 0.1KVA – 4KVA
Accuracy ±10% + 2 counts
Mains Outlet Test
Input voltage range 0-300V AC, max current 16A
Measures L – E, N – E & L – N
Accuracy ± 5% of reading + 2 counts
IEC Mains Lead Test
Test Duration 2s
Test Continuity of all conductors, Earth bond, Insulation and Polarity
General Specification
Mains Power 230 VAC ±10%, 50Hz +/- 1Hz 120 VAC ±10%, 60Hz +/- 1Hz (USA model)
Battery 6 x 1.5V Alkaline AA
Weights 1.6 kg including batteries
Size (L x W x D) 270 x 110 x 75 mm / 10.5 x 4 x 3”
Operating Conditions 0' - 40'C, 0-90% RH - NC
Storage Environment -15' - +60'C
Environmental Protection IP 40
Part Numbers
331A910 UK (13A)
331A912 Australian (10A)
331A913 Schuko (16A)
331A914 USA (15A-120V-60Hz)
331A915 Danish (13A)
331A917 French (16A)
331A918 Czech / Polish (16A)
331A919 German (16A)