• Other Seaward Sites:

Cropico 3002 - Pt100 thermometer + CVD/ ITS90

Cropico 3002 - Pt100 thermometer + CVD/ ITS90

 

Model 3002

Precision Digital Thermometer with Pt100 inputs with CVD and ITS90 Coefficients

Quality Data and Value
The Series 3000 is a digital thermometer of very high accuracy (0.01 °C) and very high resolution (0.001 °C) at an economical price. To ensure that the very best measurements are achieved, PRT probe characteristics may be entered and stored using either CVd or ITS90 coefficients. The measuring current may be reduced by 0.707 to determine self-heating of the probe and may also be reversed automatically to optimise any thermal emf errors.

Convenient and Suitable for All Applications
The Series 3000 comes with many options. 2 channel inputs which enable you to compare thermocouples directly against a standard PRT (platinum resistance thermometers). This is ideal for those wishing to calibrate thermocouples. It also lets you measure or calibrate any mix of probe types (Pt100/Thermocouple, RTD/RTD, Thermocouple / Thermocouple) and display A, B or A-B on a large LCD Graphics Panel (240x64 Dot, LED back light contrast control via keyboard). The Series 3000 is linearised for 13 thermocouples Pt25 and Pt100: the choice of which to display is yours.

Full Instrument Control
The Series 3000 can be incorporated into automated measuring systems thanks to the RS232/IEEE-488 optional interfaces.

Statistical Analysis
The Series 3000 provides a maths functions to enable the statistical analysis of stored or filtered values to be displayed (mean, max/min, peak values, standard deviations). You do not need a separate data logger. The display may also be set to display the rolling average value and standard deviation.

 

Comparison of the 3000 Series Models

3000

3001

3002

Accuracy of RTD measurement 0.01 °C

Yes

Yes

Yes

Accuracy of T/C measurement 0.1 °C

Yes

Yes

N/A

1 Millikelvin resolution for RTDs

Yes

Yes

Yes

10 Millikelvin resolution for T/C

Yes

Yes

N/A

2 measuring inputs

Yes

Yes

Yes

10 thermocouples B, E, J, K, N, R, S, T, D, C, l, U, Au/Pt

Yes

Yes

No

T/C reference junction internal or external

Yes

Yes

N/A

Pt25

Yes

No

No

Pt100

Yes

Yes

Yes

Input of RTD characteristics

Yes

Yes

Yes

Probe self-heat check

Yes

Yes

Yes

Automatic current reversal for RTDs

Yes

Yes

Yes

Suitable for 3 and 4 wire RTDs

Yes

Yes

Yes

Units °C, °F, K, mV, ohm

Yes

Yes

No

Units °C, °F, K, W

Yes

Yes

Yes

Maths function max/min, std. deviation

Yes

Yes

Yes

Data logging 4000 values

Yes

Yes

Yes

Analogue output

Option

Option

Option

RS232 talk/listen

Option

Option

Option

IEEE-488 talk/listen

Option

Option

Option

Digital Calibration

Yes

Yes

Yes

Rechargeable sealed lead acid battery

Yes

Yes

Yes

Thermocouple Type linearised as per NIST 175, ITS 90 (Model 3001)
 

Related Products

Portable Electrical Safety Testers

Precision Thermometers

 

Customer Comments

No comments have been made about this product. Be the first to let us know what you think.

Knowledge Base

You must be registered to view Knowledge Base articles related to this product. Please register or log-in to view these articles.

Key Features

  • Best Instrument for Quality Data and Lifetime Value 
  • High Accuracy 0.01 °C
  • High Resolution 0.001 °C
  • Convenient and Suitable for all Applications 
  • Compare Thermocouples / PRTs
  • Full Instrument Control with RS232 or IEEE-488
  • Statistical Analysis
  • Memory for 4000 single channel readings
  • Real Portability by Switching to Battery Power
  • Easy to Use 
  • Security and Peace of Mind

 

 

 

Downloads

There are no downloads currently available for this product.

Technical Specification

 

Type

Range °C

Resolution °C, °F or K

Display Resolution mV Uncertainty @ 20 °C ± 5° 1 year Uncertainty @ 20 °C ± 5° 60 days Temperature Coefficient /°C
B +250 to +1820 0.01 1.0 ± (0.025% Rdg + 0.006% FS)* ± (0.02% Rdg + 0.006% FS)* 7 ppm Rdg + 6 ppm FS
C 0 to +2315 0.01 1.0 ± (0.075% Rdg + 0.005% FS) ± (0.05% Rdg + 0.005% FS) 7 ppm Rdg + 6 ppm FS
D 0 to +2315 0.01 1.0 ± (0.75% Rdg + 0.005% FS) ± (0.05% Rdg + 0.005% FS) 7 ppm Rdg + 6 ppm FS
E -200 to +1000 0.01 1.0 ± (0.026% Rdg + 0.004% FS) ± (0.01% Rdg + 0.004% FS) 7 ppm Rdg + 6 ppm FS
J -210 to +1200 0.01 1.0 ± (0.03% Rdg + 0.005% FS) ± (0.008% Rdg + 0.005% FS) 7 ppm Rdg + 6 ppm FS
K -200 to +1372 0.01 1.0 ± (0.035% Rdg + 0.006% FS) ± (0.01% Rdg + 0.006% FS) 7 ppm Rdg + 6 ppm FS
N -200 to +1300 0.01 1.0 ± (0.035% Rdg + 0.005% FS) ± (0.01% Rdg + 0.005% FS) 7 ppm Rdg + 6 ppm FS
R -50 to +1768 0.01 1.0 ± (0.02% Rdg + 0.015% FS) ± (0.005% Rdg + 0.015% FS) 7 ppm Rdg + 6 ppm FS
S -50 to +1768 0.01 1.0 ± (0.02% Rdg + 0.015% FS) ± (0.005% Rdg + 0.015% FS) 7 ppm Rdg + 6 ppm FS
T -200 to +400 0.01 1.0 ± (0.025% Rdg + 0.015% FS) ± (0.005% Rdg + 0.015% FS) 7 ppm Rdg + 6 ppm FS
U -200 to +600 0.01 1.0 ± (0.025% Rdg + 0.015% FS) ± (0.005% Rdg + 0.015% FS) 7 ppm Rdg + 6 ppm FS
L -200 to +600 0.01 1.0 ± (0.03% Rdg + 0.005% FS) ± (0.008% Rdg + 0.005% FS) 7 ppm Rdg + 6 ppm FS
Au/Pt 0 to +1000 0.01 1.0 ± (0.02% Rdg + 0.015% FS) ± (0.005% Rdg + 0.015% FS) 7 ppm Rdg + 6 ppm FS

*Apply to readings above 600 C.

The above figures apply to values with the Reference Junction switched off.
Reference Junction uncertainty when used in automatic mode is better than 0.1 °C at +20 °C with a deviation of not more than 0.01 °C/ °C over the range 0 to 100 °C.

RTD Types linearised to ITS-90 Conforms to EN60751  

Type

Range   (°C)

Resistance (0hms)

Current

Resolution °C, °F or K

Resistance (ohms)

Accuracy Typically @20°C ± 5° 60 new

Pt100

-200 to -100

18 to 60

0.5mA

0.001

0.001

0.02 °C

Pt100

-100 to +500

60 to 280

0.5 mA

0.001

0.001

0.01 °C

Pt100

-500 to +800

280 to 450

0.5 mA

0.001

0.001

0.02 °C

Display LCD Graphics Panel, 240 x 64 Dot, with LED backlight contrast control via keyboard.
Inputs Thermocouples via 4mm sockets in copper block on 19mm pitch adapter plug for direct connection of thermocouple wire. Reference Junction Compensation - Automatic with internal sensor, or with external Pt100 probe. PRT¡Æs via 6-pin Lemo socket, also used for external RJ measurement.
Calibration Digital, security code protected.
Working Temperature 0..40¡ÆC rel. humidity 80% max non condensing
Storage Temperature -20...+50°C.
Mains Supply 100/120/220/240 Volts + 10% - 13% 47...63Hz max. 40VA.
Dimensions 219 x 315 x 110.3 (W D H) 1/2 19" 2.5U HIGH
Weight 12 lbs. (5.5 kg) approx.
Data Logging The 3000 Thermometers come complete with a data logging function, enabling up to 4000 single channel (2000 dual channel) readings to be stored together with a date and time stamp. The stored values can be recalled to the instrument display and scrolled through using the keyboard, alternatively these values may be downloaded to a PC file or printer.
Battery Sealed lead acid, rechargeable cell giving approximately 8 hours continuous operation. Internal battery charger.
Maths Displays max/min values Peak to Peak, Standard deviation.
Analogue Output This is a factory fitted option comprising of a single BNC socket fitted to the rear panel. The function is as per the main value display and is scaled 1mV/¡×C. A 12 bit D/A converter is used and the resolution is 0.5¡×C.
Scanner Option The scanner option may be fitted to a slot in the rear panel, two types are available for thermocouple or RTD Scanning giving a total of 8 additional measuring channels.
Interfaces The interface cards are available as an option, only one card may be fitted.
RS232 To specification ANSI/EIA/TIA/-232-E-1991.
IEEE-488 Conforms to ANSI-IEEE Std 488.1-1987.
  The interface performs the following functions: SH1, AH1,T5,TEO, L3, LEO, SR1, RL1, PPO, DC1, DT1, CO, E2.
  The interface can also be set to a talk only mode to permit stand alone printer output.

Knowledge Base

Product Matrix

The Product Matrix allows you to compare the features of up to 5 products. Simply check the box next to the products you wish to compare then select the 'Compare Products' button.

Product Enquiry

Contact Information

indicates required field
Title*
Please type in the validation code from the image (case sensitive).

Additional Information (optional)

 
Site engineered by NorthBloc   
© 2008, Seaward Electronic Group Ltd. All rights reserved.