• Other Seaward Sites:

Elite 9023 production / quality analyzer

Elite 9023 production / quality analyzer

Fully programmable electrical safety and functional test system

10A, 0-270V, AC/DC Flash, IR, EB and Leakage.

A powerful, simple to use all-in-one tester able to meet the Electrical Safety Test requirements of equipment manufacturers.

As the core of an automated test system the Elite 2 can act as a PLC controller and control up to 8 external devices, such as probes.

Using sophisticated PC software, test results can be stored and SPC analysis performed on measured data. In addition automated test sequences can be generated from the PC or Elite tester, either acting as controller.

All-in-one Electrical Safety Tester

The Elite meets all the requirements of manufacturers who need to electrically safety test their products and includes the ability to power the device under test using a programmable power source up to 280V at 10A. The tester’s capability is completed with the ability to program 8 external control ports and 8 digital ports, working as a PLC controller.

Powerful PC Software

The Elite is supplied with powerful PC software allowing the user to pre-program test sequences and store test data. The result storage capability can be used to implement Statistical Process Control (SPC) as part of a Quality Assurance (QA) program. The software has been specifically designed to provide an intuitive user interface making programming and control simple and straightforward.

The Complete Solution…..in a single unit

Single button operation, programmable sequences, powerful PC software, external control ports, run test and a full compliment of safety tests all add up to make the Elite Tester the tester of choice and the clear leader in its class.

 
 

Customer Comments

No comments have been made about this product. Be the first to let us know what you think.

Knowledge Base

You must be registered to view Knowledge Base articles related to this product. Please register or log-in to view these articles.

Key Features

 

  • Meets national and international regulations on electrical safety testing
  • All-in-one Electrical Safety Tester including load test capability
  • Powerful PC software for complete automatic control
  • Statistical analysis (SPC) and result traceability
  • Generate test sequences locally or from PC
  • Simple straightforward user interface with single button operation
  • Powerful I/O allowing control of external devices
  • Can act as PLC controller
 

Downloads

Please feel free to download any of the documents associated with this product.

Technical Specification

Earth/Ground Continuity Test

Test voltage: 12V AC nominal into an open circuit
Test current: 0 to 26A in steps of 1A
Test current accuracy: ±3%
Measurement range: 0 to 1.999W with a resolution of 0.001W
Measurement accuracy: ±2% of reading ±2 digits ±5mW
Test time: 0 to 255 seconds in steps of 1 second
Protection: thermal overload
Measurement system: 4 wire

Insulation Resistance Test

Test voltage: 200 to 1050V DC in steps of 5V
Test voltage accuracy: ±2%
Break point current: 1mA DC minimum
Short circuit current: 1.5 mA DC nominal
Capacitance drive: 1mF at 10MW
Measurement range: 0 to 20MW in steps of 10kW 19MW to 199.99MW in steps of 0.1MW
Measurement accuracy: ±2% of reading ±2 digits
Test time: 0 to 255 seconds in steps of 1 second

AC Flash/HIPOT Test

Test voltage: 100V to 5kV AC in steps of 25V
Test voltage accuracy: ±2% ±20V
Test current: 20mA AC maximum
Measurement range: 0 to 19.99mA with a resolution of 0.01mA
Measurement accuracy: ±2% of reading ±2 digits ±20mA/kV
Ramp time: 0.5 to 25 seconds in steps of 0.1 second
Dwell time: 0 to 255 seconds in steps of 1 second
Failure modes: breakdown (dv/dt > 10V/ms)
                      software trip (user selectable 0 - 19.99mA)
                      hardware trip (22mA nominal)
Discharge time: 1 second maximum
Shut down time: <20ms maximum

DC Flash/HIPOT Test

Test voltage: 200V to 6kV DC in steps of 25V
Test voltage accuracy: ±2% ±20V
Test current: 10mA DC maximum
Capacitance drive: 1mF
Measurement range: 0 to 9.99mA with a resolution of 0.01mA
Measurement accuracy: ±2% of reading ±2 digits
Ramp time: 0.1 to 25 seconds in steps of 0.1 second
Dwell time: 0 to 255 seconds in steps of 1 second
Failure modes: breakdown (dv/dt > 10V/ms)
                      software trip (user selectable 0 - 9.99mA)
                      hardware trip (11mA nominal)
Discharge time: 2 seconds maximum
Shut down time: <20ms maximum

Phase Neutral Continuity Test

Test voltage: 9 Volts DC nominal into an open circuit
Test voltage accuracy: ±2%
Test current: 8mA DC short circuit
Measurement range: 0 to 1999W with a resolution of 1W
Measurement accuracy: ±2% of reading ±2 digits
Test time: 0 to 255 seconds in steps of 1 second
Protection: protection against connection to mains

Earth Leakage Test

Test voltage: 100V to 300V in 1V increments
Test voltage accuracy: ±2%
Test current: 10mA maximum
Measurement range: 0 to 9.99mA with a resolution of 0.01mA
Measurement accuracy: ±2% of reading ±2 digits
Test time: 0 to 255 seconds in steps of 1 second

Load/Functional Testing

Test voltage: 10V to 280V in 1V increments
Test voltage accuracy: ±2% ±2V
Test current: 10A AC maximum, peak factor < 1.5
Current measurement range: 0 to 9.99A AC with a resolution of 0.01A
Current accuracy: ±2% of reading ±2 digits ±50mA
Power measurement range: 0 to 2999W with a resolution of 1W
Power accuracy: ±2% of reading ±2 digits ±5W
Slew rate: 0 to 280 V/second in steps of 1V/second
Test time: 0 to 255 seconds in steps of 1 second
Protection: thermal overload, over current trip

Screen (100 mA Earth Continuity)

Test voltage: 250mV DC maximum into an open circuit
Test current: 100mA DC constant current
Test current accuracy: ±2%
Measurement range: 0 to 1.999W with a resolution of 0.001W
Accuracy: ±2% of reading ±2 digits
Test time: 0 to 255 seconds in steps of 1 second
Protection: protection against connection to mains
Measurement system  - 4 wire

Analogue Test

Voltage input range: 0 to 10V
Measurement range: 0 to 11.99V with a resolution of 0.01V
Measurement accuracy: ±2% of reading ±2 digits
Test time: 1 to 255 seconds in steps of 1 second

Supply

Supply voltage: 230 Volts ±15% at 50 - 60Hz
Power consumption: 50VA maximum (standby) 4.25kVA maximum during functional test

Operating Temperature Range

+10°C to +30°C

Storage Temperature Range

0°C to +60°

Humidity 

0 to 80% relative humidity (non condensing)

Protection

IP43

Case Dimensions

520(w) x 210(h) x 400(d) mm approx.

Weight

E9021, E9022, E9023 29kg approx.
E9024 45kg approx.

Vibration, impact and drop rating

BSEN61010

LVD

BSEN61010

EMC

BSEN50081-1
BSEN50082-2

Indicators

Flash meter: 6kV full scale deflection
Status indicators: trip red LED, interlock open red LED, interlock closed green LED, local mode green LED, remote mode green LED

Sockets

Power supply socket: IEC320, 21A
DUT test socket: 400V, 16A 3 phase, neutral and earth IP44
Keyboard: PS2 socket for AT compatible keyboards
Serial Interface (COMM1): 9 way ‘D’ type male connector configured as an RS232 DTE (data terminal equipment)
Serial Interface (COMM2): 9 way ‘D’ male connector configured as an RS232 DCE (data communication equipment)
Control port: 16 way cage clamp connectors 230V AC @ 7A maximum rating
installation category II (IEC664)
Digital port: 16 way cage clamp connectors 12V DC output maximum
External Flash: single pole, latching socket 5kV AC maximum

Knowledge Base

Product Matrix

The Product Matrix allows you to compare the features of up to 5 products. Simply check the box next to the products you wish to compare then select the 'Compare Products' button.