Clare HAL LED

Electrical Safety Tester for LED/Luminaire Production Lines

  • High resolution power measurement
  • Tests in accordance with EN60598
  • Traceable results storage
Clare HAL LED hipot tester

Clare HAL LED hipot tester

 

Click
to Request a Quote

 Designed to ensure maximum productivity and efficiency when testing the output of LEDs and other luminaires, the Clare HAL LED features a high resolution power measurement and an internal memory for traceability of results.

The 200mVA resolution power measurement enables LED manufacturers to measure the output of each product to ensure it falls within acceptable power limits, offering peace of mind that correct components, such as LED drivers were fitted at the time of manufacture.

As well as power measurement, the Clare HAL LED also features leakage, touch current, hipot, insulation resistance and earth bond tests. The ability to configure user settings and test sequences offers flexibility for testing different types of products, and automation for faster testing.

The HAL LED's onboard memory allows accurate and comprehensive test results to be stored with date and time stamps for up to 6000 products, ensuring an audit of results for quality control systems and peace of mind.

The Clare HAL LED is designed with safety in mind; a variety of accessories are available to support compliance with EN50191 (safe test area requirements), and various design features including the isolated test outputs ensure user safety.

 

Clare HAL LED hipot tester

Click
to Request a Quote

Technical specification


AC Flash / Hipot Test

Programmable Voltage Range 0.10 kV-5.00 kV (10V/Step Resolution)
Frequency Independent of Supply 50 or 60 Hz
Voltage Display Range and Accuracy 0.10 kV-5.00kV ±1% ± 5 Counts
Voltage Display Resolution 0.01kV
Current Display Range and Accuracy 0.01mA-20.00mA ±1% ± 5 Counts
Current Display Resolution 0.01mA
Selectable Range of Pass/Fail Levels 0.01mA-20.00mA
Maximum Current Output 20.00mA @5kV
Maximum Current Output Optional Arc Detection 9 Levels

 
DC Flash / Hipot Test

Programmable Voltage Range 0.10 kV-6.00 kV (10V/Step Resolution)
Programmable Voltage Range Voltage Display Range and Accuracy 0.10 kV-6.00kV ±1% ± 5 Counts
Voltage Display Resolution 0.01kV
Current Display Range and Accuracy 0.01mA-10.00mA ±1% ± 5 Counts
Current Display Resolution 0.01mA
Selectable Range of Pass/Fail Levels 0.01mA-10.00mA
Maximum Current Output 10.00mA
Optional Arc Detection 9 Levels


Insulation Resistance Test

DC Output Voltage 250V, 500, or 1000V Selectable
Display Range 0.01MΩ-500MΩ
Display Range / Accuracy 0.03MΩ - 350 MΩ ± 5% ± 5 Counts
  350MΩ -500 MΩ Indication Only
Display Resolution 0.01MΩ
Pass/Fail Level 0.00MΩ-500.0MΩ

 
Earth / Ground Bond Test

Test Voltage Nominal 6V AC
Frequency 50 or 60 Hz (independent of supply)
Display Range and Accuracy 0-1500mΩ ±2% ±5 Counts
Display Resolution 1 mΩ
Compliance Test Ranges  
Current/Load Resistance/Time 5 A - 1000mΩ - Continuous
  10 A - 500mΩ - Continuous
  25 A - 200 mΩ - Continuous
  30 A - 150 mΩ - 60 secs
  40A - 100 mΩ - 60 secs
Settable Output Current Range 0.1A - 40.0A
Selectable Range of Pass/Fail Levels 0-1500 mΩ

 
Power and Leakage Test

Power Output Rating

Test Voltage 80V - 300V AC 20A nominal (Vin-Vout)
Maximum Power Output 999.9W

 

Output Power Measurement

Single Phase Power Measurement  
Display Range and Accuracy

+/-5% +/- 2 digits (200mV/A).
000.0 to 999.9 VA

Selectable Range of Pass/Fail Levels

000.2 - 1000 VA

 

Single Phase Power Factor Measurement

Display Range and Accuracy Ratio 0.000 -1.000 ± 0.030
Selectable Range of Pass/Fail Levels 0.000-1.000


Leakage Current Measurement

Display Range and Accuracy 0.10mA-20.00 mA ± 1% ±5 Counts
Display Resolution 0.01mA
Selectable Range of Pass/Fail Levels 0.01mA-20mA


Touch Current Measurement

Display Range and Accuracy 0.02mA - 5.00 mA ± 1% ±5 Counts
Display Resolution 0.01
Selectable Range of Pass/Fail Levels 0.02mA-5.00mA
Measuring Device IEC/EN 60990 Fig 4
  (IEC/EN 60990 Fig 3 or Fig 5 Upon Request)