SafeTest Manufacturing

Bench mounted comprehensive hipot / ground bond tester

  • Ground bond test
  • AC HiPot / dielectric testing
  • DC insulations test
  • Run, leakage test
  • Results storage
  • Collecting interface of a tag printer
SafeTest Manufacturing Hipot / Ground Bond Tester

SafeTest Manufacturing Hipot / Ground Bond Tester

Click
to Request a Quote

The SafeTest Manufacturing hipot / ground bond tester provides varying degrees of automatic test sequencing. It performs earth bond, insulation resistance, flash/hipot, leakage, short-to-line and run/load tests. It can be powered either from 110V or 230V, and can test both 110V and 230V products, irrespective of main voltage.

Easy to operate with a full QWERTY keypad and/or barcode scanner, and includes full-on screen user instructions.

The SafeTest Manufacturing hipot / ground bond tester meets the needs of manufacturers who require a range of fundamental safety tests to be carried out on a variety of electrical and electronic products to CE, UL, CSA, TUV, Intertek or other standard certifying test laboratories and other international standards. All tests are individually selectable and the tester can be easily customized with pre-programmed product specific test sequences with preset durations and thresholds for automatic execution, simplifying training and operator interaction. Configurations are safeguarded via password protection, ensuring that test sequences are only altered by authorized personnel.

The SafeTest Manufacturing hipot / ground bond tester provides a range of fundamental safety tests for all luminaire product, with a simple PASS/FAIL message to the operator.

The Safe Testing Manufacturing’s internal memory has the capacity to store the results of 6,000 tests. An optional safety label printer enables the automatic production of test tags, labels and test reports. Clever use of the optional barcode scanner (for product identification and tester configuration) means this product can be integrated easily into a typical ISO quality control system. Each test can also be run in manual mode.

SafeTest Manufacturing Hipot / Ground Bond Tester

Click
to Request a Quote

Technical specification

Flash/Hipot Test (Class I)

Test Voltage Class I 1.5kV AC
Display Range 0.1 – 10.00mA
Resolution 0.01mA
Accuracy +/- 5% +/- 2 digits
Pass Levels Selectable up to 10mA

Flash/Hipot Test (Class II)

Test Voltage Class II 3.0kV AC
Range 0.1 – 10.00mA
Resolution 0.01mA
Accuracy +/- 5% +/- 2 digits
Pass Levels Selectable up to 10mA

Earth/Ground Bond Test

Test Voltage 6VAC (open circuit)
Test Currents 25A, 10A, 4A, 100mA AC into short circuit
Range 0.04 - 20Ω
Resolution 1mΩ
Accuracy +/- 5% +/- 2 digits
Pass Levels User selectable

DC Insulation Test

Test Voltages 250V, 500VDC
Range 100k - 50M
Accuracy +/- 5% +/- 2 digits

Earth Leakage (Load Leakage)

Voltage Mains Supply
Range 0.1 – 20mA
Resolution 0.01 mA
Accuracy +/- 10% +/- 2 digits (1.00 – 20mA)
Pass Levels Selectable up to 10 mA

Substitute Leakage (Short to case test)

Voltage 40VAC nominal at 230V/110V supply
Range 0.1 – 20mA
Resolution 0.01 mA
Accuracy +/- 10% +/- 2 digits (1.00 – 20 mA)
Pass Levels Selectable up to 15 mA

Power/Run/Load Test

Measured Load 0 – 4.2kVA
Resolution 0.01 kVA
Accuracy +/- 10% of reading, +/- 2 digits

Polarity

Test performed Live & Neutral continuity & polarity

External Connections

Serial Port
Parallel Port
Guard Switch
Beacon

General Specifications

Dimensions (w x h x d): 450 x 410 x 155mm / 17.7 x 16.1 x 6.1”
Weight: 9kg / 19.8lb
Operating Voltage Range: 103V – 126V, 207V – 253V, 45Hz – 65Hz
Operating Temperature: 0 – 40°C
EN 50191: Compliant when used with appropriate accessories

Supplied with

HT Probe
Earth Bond Lead
Guard with Plug
Instruction Manual
Calibration certificate

Optional Accessories

Barcode scanner (194A922)
Serial printer lead (283A955)
Serial-PC lead (9-9 way) (194A919)
Serial-PC lead (9-25 way) (194A920)
Desk Test n Tag printer (supplied with 100x50mm labels) (312A916)
Desk Test n Tag printer (supplied with 35x45mm labels) (312A973)
Guard switch (DCS317)
Beacon (H-5027)
Beacon connector lead (H-5028)

Software

PATGuard 3 Elite software
Download your 30 day free trial at www.seaward.co.uk/PG3trial

Services

1 year warranty (subject to product registration with Seaward.
Visit www.seaward.co.uk/register-product)

Go to www.calibrationhouse.com or www.seaward-groupusa.com/service-center for more information about our services and calibration

Part number

313A910