ClareHAL Series

Advanced Hipot / Ground Bond Tester

  • Available in different configurations to suit individual testing requirements
  • HiPot/Dielectric strength test
  • Ground Bond testing up to 40 amps
  • DC Insulation testing
  • Power, run, leakage, load, power factor
  • Internal memory to store results
  • Communication with Tag printers
ClareHAL Series Hipot/Ground Bond Tester

ClareHAL Series Hipot/Ground Bond Tester

Click
to Request a Quote

COMPLIANCE – Standards and Directives

Validation testing is essential for manufacturers to ensure compliance with NRTL product test requirements including UL/CE marking.

Electrical safety testing specialists Seaward have produced the HAL series that perform all of the applicable tests needed for insuring compliance with UL type tests, EU Directives, International, European and UK standards in one convenient package.

The ClareHAL hipot / ground bond tester will help you meet your testing and legal obligations, including data capture/logging/archiving. All basic tests, as specified in widely used product and safety standards, are included:

  • Earth/Ground Bond testing
  • DC Insulation Testing
  • AC/DC Flash/Hipot/Dielectric withstand testing
  • Functional/ Run testing
  • Leakage Current testing
  • The ClareHAL Tester can be used in three modes – automatic, manual and direct PC control via the external communications port.

Automatic Mode
In automatic mode complete test sequences are stored in the memory. New sequences are easily programmed using testcodes, or via menu driven choices. Up to 5 tests can be linked into 1 sequence, all tests are time stamped and results can be stored in memory. Automatic mode provides a structured, repeatable route to testing which ensures all data is collected for traceability and auditing. This mode is intended for standard production line use.

Manual Mode
Manual mode provides a quick, simple route to tests and is intended for use in the laboratory, repair or re-test environments where ease of use and quick repeatable tests are are paramount. Manual mode can be initiated by a one button press and allows individual tests to be performed more freely. The type of test and its parameters are entered into the tester. The output can be maintained continuously, varied by means of the rotary encoder or timed as in automatic mode. A facility to store results is available although this is not necessary to perform tests.

ClareHal 104 + Safety e-Base Pro

Seaward have created Safety e-Base Pro, a specially designed software program that improves the flexibility, traceability and productivity of the ClareHAL 104 Hipot / Ground Bond Tester.

  • Human error is reduced and efficiency increased by controlling tests remotely from your PC.
  • Create your own test sequences which begin on user-defined trigger commands.
  • Test sequences can be customized for different standards and products, allowing your test system to always be up-to-date.
  • The test process is made easier for the operator by programmable prompts in picture or text format.
  • Save your test results automatically on your PC to improve traceability and auditability

Using Safety e-Base Pro alongside the ClareHal 104 ensures all production line testing is being conducted safely, efficiently and to the correct requirements. Safety e-Base Pro gives you all the benefits of a bespoke test system by being customizable to your specific requirements.
Click to Request a Quote or get in touch if you have any questions.

ClareHAL Hipot / Ground Bond Series Comparison
Features 100 101 102 103 104
Earth/Ground Bond    
AC Flash/Hipot  
DC Flash/Hipot  
DC Insulation Resistance  
ARC Detection  
Leakage        
Load Power        
Power Factor        
Results Memory
Automation Option
Barcode scanner/printer Option
Internal scanner        

ClareHAL Series Hipot/Ground Bond Tester

Click
to Request a Quote

Technical specification


AC Flash / Hipot Test

Programmable Voltage Range 0.10 kV-5.00 kV (10V/Step Resolution)
Frequency Independent of Supply 50 or 60 Hz
Voltage Display Range and Accuracy 0.10 kV-5.00kV ±1% ± 5 Counts
Voltage Display Resolution 0.01kV
Current Display Range and Accuracy 0.01mA-20.00mA ±1% ± 5 Counts
Current Display Resolution 0.01mA
Selectable Range of Pass/Fail Levels 0.01mA-20.00mA
Maximum Current Output 20.00mA @5kV
Maximum Current Output Optional Arc Detection 9 Levels

 
DC Flash / Hipot Test

Programmable Voltage Range 0.10 kV-6.00 kV (10V/Step Resolution)
Programmable Voltage Range Voltage Display Range and Accuracy 0.10 kV-6.00kV ±1% ± 5 Counts
Voltage Display Resolution 0.01kV
Current Display Range and Accuracy 0.01mA-10.00mA ±1% ± 5 Counts
Current Display Resolution 0.01mA
Selectable Range of Pass/Fail Levels 0.01mA-10.00mA
Maximum Current Output 10.00mA
Optional Arc Detection 9 Levels


Insulation Resistance Test

DC Output Voltage 250V, 500, or 1000V Selectable
Display Range 0.01MΩ-500MΩ
Display Range / Accuracy 0.03MΩ - 350 MΩ ± 5% ± 5 Counts
  350MΩ -500 MΩ Indication Only
Display Resolution 0.01MΩ
Pass/Fail Level 0.00MΩ-500.0MΩ

 
Earth / Ground Bond Test

Test Voltage Nominal 6V AC
Frequency 50 or 60 Hz (independent of supply)
Display Range and Accuracy 0-1500mΩ ±2% ±5 Counts
Display Resolution 1 mΩ
Compliance Test Ranges  
Current/Load Resistance/Time 5 A - 1000mΩ - Continuous
  10 A - 500mΩ - Continuous
  25 A - 200 mΩ - Continuous
  30 A - 150 mΩ - 60 secs
  40A - 100 mΩ - 60 secs
Settable Output Current Range 0.1A - 40.0A
Selectable Range of Pass/Fail Levels 0-1500 mΩ

 
Power and Leakage Test

Power Output Rating

Test Voltage 110V - 230V AC 20A nominal (Vin-Vout)
Maximum Power Output Up to 5.0kVA (dependant on mains supply rating)

 

Output Power Measurement

Single Phase Power Measurement  
Display Range and Accuracy 0.02kVA-5.00kVA ±2% ±0.02kVA
Selectable Range of Pass/Fail Levels 0.001kVA-5.000kVA

 

Single Phase Power Factor Measurement

Display Range and Accuracy Ratio 0.000 -1.000 ± 0.030
Selectable Range of Pass/Fail Levels 0.000-1.000


Leakage Current Measurement

Display Range and Accuracy 0.10mA-20.00 mA ± 1% ±5 Counts
Display Resolution 0.01mA
Selectable Range of Pass/Fail Levels 0.01mA-20mA


Touch Current Measurement

Display Range and Accuracy 0.02mA - 5.00 mA ± 1% ±5 Counts
Display Resolution 0.01
Selectable Range of Pass/Fail Levels 0.02mA-5.00mA
Measuring Device IEC/EN 60990 Fig 4