PrimeTest 200 Portable Safety Tester & DMM

PrimeTest 200 Portable Safety Tester & DMM

3–in–1 Electrical Safety Multi – Tester

The next generation of hand–held tester – the first ever tester to combine the function of these separate testers into a single instrument:

Electrical Safety Tester + Installation Checker + Digital Multimeter = PrimeTest 200

Giving you even greater efficiency, speed of testing and convenience!

Combine the testing requirements needed of safety tester, installation checker and DMM and you have the PrimeTest 200. The ergonomically designed hand-held unit, with integral rubber bumpers, provides 10 measurement functions including temperature (via a module) and is capable of testing all 110V electrical appliances, power tools, extension cords, and most electrical equipment.

Suitable for those working in maintenance and repair as well as electricians and electrical contractors.

Customer Comments

No comments have been made about this product. Be the first to let us know what you think.

Knowledge Base

You must be registered to view Knowledge Base articles related to this product. Please register or log-in to view these articles.

Key Features

 

  • Battery powered for maximum portability
  • Rotary switch test selection
  • Single Test button action
  • Tests Class I and Class II equipment including IT and business equipment, extension cords, and almost any electrical appliance or tool
  • IEC Lead tests
  • Insulation, Continuity, Socket polarity and GFCI tests
  • Loop resistance indication without GFCI trip
  • Voltage (AC and DC)
  • Temperature Measurement (with optional accessory module using a type K thermocouple)
  • Large LCD display with analogue bar graph and back light
  • Battery life indicator
  • Lead compensation up to 10W for ground continuity & low resistance measurement
  • Continuity buzzer
  • Lock for continuous measurement
  • Auto power off when not in use
  • Supplied with batteries, lead set, IEC lead, instruction manual and deluxe carry case with shoulder strap

Downloads

Please feel free to download any of the documents associated with this product.

Technical Specification

Ground Continuity
 
Output Current (Load 2W): +/- 200mA DC
Test Voltage (o/c): > 4VDC
Test Duration (Class I test): 2s
Range & Accuracy: 0.01 - 20W +/-5% 2 counts
Max. Resolution: 0.01
W
Analog Bar Graph: 0 to 20W
Bar Graph Accuracy: 10%
Pass Value (Class I test): 0.2W

Insulation Test
 
Test Voltages: 500VDC @ 1mA nominal, < 2mA (s/c)
Test Voltage Accuracy: +20%, -0%
Duration (Class I or Class II tests): 2s
Auto Range: 2.00MW, 20.0MW 200MW
Accuracy: ±2% +2 digits, 2MW 20MW, 200MW ranges
Resolution: 0.01MW from 0 to <2.00MW,
0.1MW from >2.0MW to <20.0MW,
1MW from 20 MW to <200MW
Analog Bar Graph: 0 to 200MW
Bar Graph Accuracy: 10%
Pass Value: 2MW

IEC Lead Test

Test Voltage: 9VDC
Test Duration: 2s
Test: Live / Neutral Checks for o/c, s/c and crossed

Digital Multimeter MEASUREMENTS

Continuity
     
Output Current (Load2W): 200mA DC
Test Voltage (o/c): > 4VDC
Range: 0.01 – 20kW, auto ranging at appropriate points.
Accuracy: ±2% +/-2 counts to 20W
               ±5% +/-2 counts to 20kW
Resolution: 0.01W from 0.01W to 19.99W
                 1W from 20W to 1999W
                 10W from 2.00 kW to 20.00 kW
Analog Bar Graph: 0 to 20kW
Bar Graph Accuracy: 10%

Voltage Measurement
 
Range & accuracy: 120V AC/DC to 400Hz; 2% +2 counts
Resolution: 1V
Analog Bar Graph: 0 to 600V
Bar Graph Accuracy: 10%
Visible Warning: 30V AC or DC at inputs
Accuracy: +/- 2% of reading +/- 2counts

Temperature Measurement
 
Measuring Range: -50°C to 400°C
Accuracy: +/- 5% of reading +/- 2digits
Resolution: 0.1°C

POWERED TESTS

Touch Current
 
Test voltage: Supply Voltage, max current 10A
Test Duration: 2s – 30s nominal
Range & Accuracy: 0.1 – 3.5mA; +/- 10% of reading ± 2 digits 
Resolution: 0.01mA
Frequency Response: DC – 2.5KHz

Pass Value: 0.25mA


Differential Leakage
 
Test Voltage: Supply Voltage, max current 10A
Test Duration: 2s – 30s nominal
Range Accuracy: 0.1 – 20mA; +/- 5% of reading +/- 2 digits
Conductor Current Resolution: 0.01mA
Frequency Response: 40Hz – 2.5 kHz
Pass Value: 0.25mA


GFCI Test
 
Test Current: 30mA rms sinusoidal, starting on a zero crossing at 0° followed by 180°
Test Current Accuracy: +5%, -0%
Test Duration: 500 ms maximum if GFCI does not trip
Display Range: 0 – 500ms
Accuracy: +/- 10% of reading +/- 2 digits
Resolution: 1ms
Interlock: Test inhibited if Phase – Neutral or Phase - Ground voltage is not correct or a voltage over 40 V exists between neutral and protective earth
Pass Value: 200mS

Power Socket Test
 
Input voltage range: 100 – 240V AC max current 10A
Voltage potential: Indicates configuration of:
 Line potential phase to earth, Line potential phase to neutral, Line potential neutral to earth

Earth Loop Resistance Check: The earth loop resistance is automatically measured when the mains, is detected and the unit is in the RCD switch position.
Ranges: <2W <10W <20W <50W <100W >100W 

GENERAL

Power Source: 6 x AAA Type disposable Cells
Incoming Supply voltage: 120 V ac, 60Hz input, max current 10A 
Dimensions & Weight: 4.6" (w) x 2.3" (d) x 11.3" (l); 1.8 lbs.

Knowledge Base

Product Matrix

The Product Matrix allows you to compare the features of up to 5 products. Simply check the box next to the products you wish to compare then select the 'Compare Products' button.

Product Enquiry

Contact Information

indicates required field
Title*
Please type in the validation code from the image (case sensitive).

Additional Information (optional)

 
Site engineered by NorthBloc