Visual inspection entries via keyboard +
| |
|
Protective Bonding | |
|
Test Current |
>10A into 0.33W (EN60204-1) |
|
Selectable |
|
|
Test Current |
Auto Compensating |
|
Measuring Range |
0.05 - 5V |
|
Test Thresholds |
1.0, 1.4, 1.9, 2.6, 3.3V |
|
Test Voltage |
6V O/C @ supply Hz |
|
Accuracy |
±8% ±4 digits |
|
Method |
4 wire (Kelvin) |
|
Test Duration |
5, 10, 20, 60 seconds - selectable |
|
Insulation | |
|
Test Voltage |
500V DC @ 1mA |
|
S/C Current |
<10mA |
|
Measuring Range |
0.1 - 300mW |
|
Pass/Fail |
|
|
Thresholds |
1.0mW |
|
Accuracy |
±8% ±2 digit 0.1 - 50mW |
|
Test Duration |
5, 10, 20, 60 seconds - selectable |
|
Voltage Test | |
|
EN60204 | |
|
Test Voltage1 |
>1000V O/C @ supply Volts |
|
Test Current |
>0.5A |
|
Measuring |
|
|
Indication |
Pass/Fail |
|
Test Duration1 |
1, 2, 5, 10 seconds |
|
EN60439 | |
|
Test Voltage2 |
>2500V O/C @ supply Hz |
|
Test Current |
>20mA max |
|
Test Threshold |
5, 10, 15, 20, 500mA |
|
Test Duration1 |
1, 2, 5, 10 seconds |
|
Residual Voltage | |
|
Input Range3 |
0 - 500AC/DC |
|
Measuring |
|
|
Indication |
30 - 370V |
|
Test Threshold |
60V |
|
Accuracy |
±8% |
|
Test Duration |
1, 5 seconds - selectable |
|
External Sense |
|
|
Voltage |
50 - 500 AC 50/60Hz |
|
Operations Test | |
|
Measuring Range4 |
0 - 4.0kVA |
|
Accuracy |
±5% ±130kVA |
|
Test Duration1 |
0.5, 1, 5, 15 minutes |
|
General | |
|
Supply Voltage |
120V (60 - Hz) |
|
Dimensions |
16.2" x 14.6" x 6.3" |
|
Weight |
22 lbs. |