Bench top comprehensive Tool and Appliance tester for Service, Tool Cribs, Maintenance depots and rental stores
- HiPot
- Ground Bond testing
- DC Insulation Resistance
- Load and Leakage test
- Power cord and extension cord testing
- Storage of results
The Safecheck 8 power tool tester tests, records your test data and prints safety tags. A truly professional solution not only ensures the safety of power tools and appliances but also records the information to prove precaustions have been taking to provide a safe working environment.
The Safecheck 8 power tool tester is ideal for rental companies, power utilities, constructions sites, education, small and medium industrial commercial organizations where safety is paramount.
The Safecheck 8 power tool tester performs manual or automatic test sequences for tools, appliances or power cords. With its internal memory it can store up to 6000 test results before downloading to a PC or printer.
When used with the Desk Test N' Tag printer, tags are automatically printed out for attachment to the tool or appliance providing clear visual evidence of testing and compliance with OSHA's Grounding programme.
This complete safety system can be purchased as individual items or as a complete kit.
SafeCheck 8 Power Tool Tester
| Test Voltage Class I | 1.25kV AC |
| Display Range | 0.1 - 10 mA AC |
| Resolution | 0.01mA |
| Accuracy | +/- 5% +/- 2 digits |
| Pass Levels | selectable up to 10mA |
| Test Voltage Class II | 2.5 kV AC |
| Display Range | 0.1 - 10 mA AC. |
| Resolution | 0.01mA |
| Accuracy | +/- 5% +/- 2 digits |
| Pass Levels | selectable up to 10mA |
| Tests Voltage | 500V |
| Display Range | 0.1 - 99.99MΩ |
| Accuracy | +/- 5% +/- 2 digits (up to 19.99MΩ) |
| Test Voltage | 6V AC (open circuit) |
| Test Current | 25A, 10A, 4A, 100mA AC into short circuit |
| Range | 0.04Ω - 20Ω |
| Resolution | 1mΩ |
| Accuracy | +/- 5% +/- 2 digits |
| Pass Levels | user selectable |
| Test Voltage | 40V AC o/c |
| Display Range | 0.1 - 20.0mA AC |
| Resolution | 0.01mA |
| Accuracy | +/- 10% +/- 2 digits (1.00 - 20mA) |
| Pass Levels | selectable up to 15mA |
| Test Voltage | Mains Supply |
| Display Range | 0.1 - 20.0mA AC |
| Resolution | 0.01mA |
| Accuracy | +/- 10% +/- 2 digits (1.00 - 20mA) |
| Pass Levels | selectable up to 10mA |
| Resolution | 0.01kVA |
| Measured Load | 0 - 4kVA |
| Accuracy | +/- 10 of reading, +/- 2 digits |