Rigel UNI-SIM Vital Signs Simulator

NIBP / SPO2 and ECG Simulator

  • Accurate 6 in 1 vital signs simulation
  • Hand-held and Battery powered
  • On-board memory and keyboard
Rigel UNI-SIM Vital Signs Simulator

Rigel UNI-SIM Vital Signs Simulator

Click
to Request a Quote

The Rigel UNI-SiM is the world’s first battery powered 6 in 1 vital signs simulator able to undertake six synchronized vital signs parameters tests.

Enabling quick, easy and accurate simulations of NiBP, SpO2, ECG, temperature, IBP and respiration functionality, the Rigel Uni-Sim is one of the most valuable tools around today.

Utilizing new and advanced technologies in both SPO2 and NIBP simulation, reduces errors and minimizes the test time. Manufacturer specific simulation curves can be created and uploaded to further aid the accuracy.

Bluetooth connectivity to a range of accessories and Med-eBase, comprehensive database software, ensures fast and easy download of test results, managing your asset database, creation of test sequences and producing test certificates.

The Rigel PULS-R SpO2 Finger Simulator can also be used with the UNI-SiM vital signs simulator

Rigel UNI-SIM Vital Signs Simulator

Click
to Request a Quote

Technical Specification:

Non-invasive Blood Pressure
Simulation Waveform Oscillometric
Integrated Pump 0 to 350 mmHg user configurable
Leak Test User configurable between 0-350mmHg
Chronometer Configurable upto 999 secs
Digital Manometer 0 - 410 mmHg
Pressure Accuracy +/- 0.5% FS
Pressure Units mmHg, inHg, kg/cm2, cmH2O, mBar, PSI, inH2O and kPa
Oxygen Saturation
Range 50 to 100%
Accuracy ± 1 bpm
Chronometer Test option to test response time SpO2 monitor
ECG Arrhythmia Simulator
ECG 5 lead simulation including high level output
Wave Forms Normal Sinus Rhythm (NSR), ST Elevation, ST Depression, Myocardial Infarction, Tall T
Rate 20 – 300 BPM typed value
Performance Waveforms Sine, Square, Triangle, and Pulse
Pacer Waveforms Synchronous Atrial, Asynchronous Atrial
Pacer Only Pacer Pulse rate 60 BPM, Ventricular Pacer rate 70 BPM, Atrial & Ventricular Pacer Heart rate 70 BPM, R Wave Detection
Arrhythmia Waveforms
Atrial Sinus Arrhythmia (SA), Missing beat, Atrial Flutter (AFLT), Atrial Fibrillation (AFB), Paroxysmal Atrial Tachycardia (PAT), Junctional Premature Contraction
Atrial Conduction First Degree AV Block, Second Degree AV Block - Mobitz I, Second Degree AV Block - Mobitz II, Third Degree AV Block, Right Bundle Branch Block (RBB), Left Bundle Branch Block (LBB), Left Anterior Hemiblock
Ventricular Premature Ventricular Contraction - Intermittent Premature Ventricular Contraction – Continuous, Bigeminy, Trigeminy, Ventricular Flutter (VFLT), Ventricular Fibrillation (VFB), Ventricular Tachycardia (VTC), Right Focal PVC
Temperature
Simulation YSI 400 / 700 Static
Range Preset at 25, 33, 37and 41°C
Respiration
Rates 5, 10, 15, 30, 60, 120, 180 Breaths per Minute
Base Resistances 250, 500, 750, 1000 ohms
Apnoea Simulation 0 – 60 seconds duration 0 – 300 seconds interval
Invasive Blood Pressure
Channels 2 channels
Static 0 to 300mmHg. Typed values
Dynamic 0 - 300mmHg for systolic & diastolic
General Specification
Operation Battery cell, insitu charge
Battery Charger 110-230VAC, 50/60 Hz
Battery Life 4-24 hours testing depending on simulations
Memory Capacity Approximately 10,000 records
Communication Via Blue Tooth
Display Monochorme, ¼ VGA full graphics
Keypad Alpha-numeric
Weight <1.5 kg
Size (L x W x D) 270 x 110 x 75 mm / 10.5 x 4 x 3”
Operating Conditions 10-30°C, 0-90% RH - NC
Storage Environment -15°C - +60°CC
Environmental Protection IP 40